24VDC Magnetic Latching Contactor Miniature 12V Relay

Products

24VDC Magnetic Latching Contactor Miniature 12V Relay

24VDC Magnetic Latching Contactor Miniature 12V Relay

Cautions of Latching Relay: 1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical

Send your inquiry

DESCRIPTION

Basic Info.
Model NO. IM801D
Protective Characteristics Enclosed Rlay
Action Principle Electromagnetic Type
Size Miniature
Type Electric Parameter Relay
Coil Voltage 5~48VDC
Certificate Appearance Patent
Color Black
Rated Load 80A, 250VAC
Contact Material Agsno2
Transport Package Cartons/Pallet
Specification 62.8*35*21.8mm
Trademark IVY
Origin Zhejiang, China
HS Code 8536411000
Production Capacity 5, 000, 000.00/ Year
Product Description

24VDC Magnetic Latching Contactor Miniature 12V Relay

24VDC Magnetic Latching Contactor Miniature 12V Relay

24VDC Magnetic Latching Contactor Miniature 12V Relay

Basic DataDimension(mm)62.8×35×21.8
Weight ( g )78g
Contact Arrangement2A/2B
Contact MaterialAgSnO2
Ambient Temperature-40~+70ºC
Ambient Humidity45%~90%RH
Vibration10~55Hz,1.5mm(DA)
Specification DataNominal Voltage5~48VDC
Power ConsumptionSingle Coil:2W, Dual Coil:4W
Max. Switching Voltage250VAC
Max. Switching Current80A
Max. Switching Power20000 VA
Contact Resistance<1.0 mΩ
Insulation Resistance1000MΩ(DC 500V)
Dielectric Creepage8mm
Dielectric StrengthAcross Open Contact>2000VAC 1min
Coil To Contact>4000VAC 1min
Electrical Life>10,000cycles
Mechanical Life>100,000cycles
Picking-up & Release Time<=30ms
Pulse Duration>=100ms
Functional Shock Resistance10G
Destructive Shock Resistance100G

24VDC Magnetic Latching Contactor Miniature 12V Relay

24VDC Magnetic Latching Contactor Miniature 12V Relay

Cautions of Latching Relay:
1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,

you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.

(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5

times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.

2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after

the installation.

(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is

fastened and prevent relay from damages or other safety problems due to temp. Rise..

(3)The sampling signal wires of products are limited, please do not pull or torque during installation.