Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Products

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Cautions of Latching Relay: 1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical

Send your inquiry

DESCRIPTION

Basic Info.
Model NO. IM901T
Protective Characteristics Sealed Relay
Action Principle Electromagnetic Type
Size Miniature
Type Electric Parameter Relay
Max. Switching Power 22500 Va
Power Consumption Single Coil:3.0W, Dual Coil:6.0W
Picking-up & Release Time Less Than or Equal to 20ms
Ambient Temperature -40~+70 Degree
Contact Material Agsno2
Max. Switching Current 90A
Product Name 90A 3p Smart Meter Latching Relay
Max. Switching Voltage 250VAC
Contact Arrangement 3A/3b
Nominal Voltage 6~48VDC
Transport Package Cartons/Pallet
Specification 98*40*35.7mm
Trademark IVY
Origin Zhejiang, China
HS Code 8536411000
Production Capacity 800, 000.00/ Month
Product Description

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Basic DataDimension(mm)98*40*35.7
Weight ( g )/
Contact Arrangement3A/3B
Contact MaterialAgSnO2
Ambient Temperature-40~+70ºC
Ambient Humidity45%~90%RH
Vibration10~55Hz,1.5mm(DA)
Specification DataNominal Voltage6~48VDC
Power ConsumptionSingle Coil:3.0W, Dual Coil:6.0W
Max. Switching Voltage250VAC
Max. Switching Current90A
Max. Switching Power22500 VA
Contact Resistance<2 mΩ
Insulation Resistance1000MΩ(DC 500V)
Dielectric StrengthAcross Open Contact>2000VAC 1min
Coil to Contact>4000VAC 1min
Electrical Life>10,000cycles
Mechanical Life>100,000cycles
Picking-up & Release Time<=20ms
Pulse Duration/
Functional Shock Resistance10G
Destructive Shock Resistance100G

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay

Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay



Cautions of Latching Relay:
1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status. 2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or afterthe installation.(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection isfastened and prevent relay from damages or other safety problems due to temp. Rise..(3)The sampling signal wires of products are limited, please do not pull or torque during installation.