Three Phase UC3 80A 12V 24VDC 250VAC Magnetic Latching Relay
Cautions of Latching Relay: 1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical
Send your inquiryDESCRIPTION
Basic Info.
Model NO. | IM901T |
Protective Characteristics | Sealed Relay |
Action Principle | Electromagnetic Type |
Size | Miniature |
Type | Electric Parameter Relay |
Max. Switching Power | 22500 Va |
Power Consumption | Single Coil:3.0W, Dual Coil:6.0W |
Picking-up & Release Time | Less Than or Equal to 20ms |
Ambient Temperature | -40~+70 Degree |
Contact Material | Agsno2 |
Max. Switching Current | 90A |
Product Name | 90A 3p Smart Meter Latching Relay |
Max. Switching Voltage | 250VAC |
Contact Arrangement | 3A/3b |
Nominal Voltage | 6~48VDC |
Transport Package | Cartons/Pallet |
Specification | 98*40*35.7mm |
Trademark | IVY |
Origin | Zhejiang, China |
HS Code | 8536411000 |
Production Capacity | 800, 000.00/ Month |
Product Description
Basic Data | Dimension(mm) | 98*40*35.7 | |
Weight ( g ) | / | ||
Contact Arrangement | 3A/3B | ||
Contact Material | AgSnO2 | ||
Ambient Temperature | -40~+70ºC | ||
Ambient Humidity | 45%~90%RH | ||
Vibration | 10~55Hz,1.5mm(DA) | ||
Specification Data | Nominal Voltage | 6~48VDC | |
Power Consumption | Single Coil:3.0W, Dual Coil:6.0W | ||
Max. Switching Voltage | 250VAC | ||
Max. Switching Current | 90A | ||
Max. Switching Power | 22500 VA | ||
Contact Resistance | <2 mΩ | ||
Insulation Resistance | 1000MΩ(DC 500V) | ||
Dielectric Strength | Across Open Contact | >2000VAC 1min | |
Coil to Contact | >4000VAC 1min | ||
Electrical Life | >10,000cycles | ||
Mechanical Life | >100,000cycles | ||
Picking-up & Release Time | <=20ms | ||
Pulse Duration | / | ||
Functional Shock Resistance | 10G | ||
Destructive Shock Resistance | 100G |
Cautions of Latching Relay:
1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status. 2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or afterthe installation.(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection isfastened and prevent relay from damages or other safety problems due to temp. Rise..(3)The sampling signal wires of products are limited, please do not pull or torque during installation.