UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two

Products

HomeHome / Products / Power Relay / Details
UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two

UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two

Product Description AC switching elements are a crucial part of safety and protection function in charging stations and

Send your inquiry

DESCRIPTION

Basic Info.
Model NO. IM-NE801
Protective Characteristics Sealed Relay
Action Principle Electromagnetic Type
Size Miniature
Type Electric Parameter Relay
Mechanical Endurance 1*10^6OPS
Pick-up & Release Time 30ms. Typical/10ms. Typical
Electrical Endurance 5*10^5OPS
Initial Contact Resistance 10mohm (at 20A)
Dielectric Strength 500vrms, 1 Min
Weight 70g
Shock Resistance 20g, 11ms
Environment Temperature Operation: -40 Degree~85 Degree
Contact Form 2A/2b
Contact Distance 3mm
Continuous Current 40A
Dielectric Withstanding Voltage 4000VAC 1 Min
Max. Switching Voltage 277VAC
Contact Material Agsno2
Transport Package Bag, Box, Carton, Pallet
Specification 30*26.5*49mm
Trademark IVY
Origin Zhejiang, China
HS Code 8536411000
Production Capacity 5, 000, 000.00/ Year
Product Description

Product Description

AC switching elements are a crucial part of safety and protection function in charging stations and PV system.

As an important part of the solar power generation system, the photovoltaic inverter can convert the DC current output generated from the photovoltaic panel into AC current, which can then be incorporated into the commercial grid or other off-grid power systems. In the grid connection interface, the electromagnetic relay on the AC side of the inverter plays a key role as a switching device to provide the necessary safe "open circuit" function.

IM-NE801A is a two-pole PCB power relay for new energy power generation(EV Charger, Solar Inverter, Energy Storage System). It features a high-capacity resistive switching load rating of [email protected] for 50K cycles (@32A 230VAC) or 20K cycles (@40A 230VAC). The relay also features a mirror contact structure (compliant with EN60947-4-1) which uses a 2 Form A contact arrangement. IM-NE801A has a normally open contact gap of 3mm, which makes this relay VDE0126 compliant with European photovoltaic standards and meets the 4kV surge breakdown voltage between contacts required to be compliant with the EN61810-1 Industry standard.

The relay has short-time overcurrent characteristics, can withstand three times of 1000A 1ms overcurrent, and the contacts will not be damaged, and can continue to work normally to open and close.

Short-time overcurrent (an overcurrent carrying capacity)

UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two-Pole PCB PV Power Relay for Solar Inverter

UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two-Pole PCB PV Power Relay for Solar Inverter

SpecificationWeight≈70g
Continuous Current40A
Contact Form2A/2B
Contact MaterialAgSnO2
Max. Switching Voltage277VAC
Initial Contact Resistance10mΩ (at 20A)
Insulation Resistance100MΩ,at 500VDC,50% RH
Electrical Endurance

50000 [email protected] 230VAC on-off ratio 1s:9s

20000 [email protected] 230VAC on-off ratio 1s:4s

Mechanical Endurance1*106 ops
Dielectric withstanding voltageAcross Open Contact4000VAC 1min
Coil to Contact801:3000VAC 1min
801A: 4000VAC 1min
Pick-up & Release Time30ms. typical/10ms. typical
Environment TemperatureOperation:-40ºC~85ºC
Storage:-40ºC~125ºC
Vibration10-40Hz,DA1.27mm, 40-70Hz:5g
70-100Hz:DA0.5mm,100-500Hz:5g
Shock Resistance:20g, 11ms
Dielectric Strength500Vrms, 1 min

UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two-Pole PCB PV Power Relay for Solar Inverter

UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two-Pole PCB PV Power Relay for Solar Inverter

UL/CE/VDE 3mm Contact Gap 40A 277VAC 24VDC Two-Pole PCB PV Power Relay for Solar Inverter

Cautions of New Energy Relay:
1.Ordering Information
1.1 The biggest differences between this new energy relay and traditional latching relay or power relay are:
the wider contact distance and stronger dielectric strength of 4000Vac instead of 1500 /2000Vac.
So the contact distance can be 3mm or normal type.
1.2 The nominal voltage of coil are 12Vdc and 24Vdc with the low power consumption of 1.8W or 3W.
Plz note that you should drive the circuit/coil with step-down voltage to ensure power consumption of 1W~1.5W.
1.3 Two poles of contacts of this relay, it means it can control 2 circuits and the default status is 2A- normally open. Simply put, if you buy it as ev relay then most time the relay is open and not work, some times they are closed when charging.
1.4 For environment-friendly, you can also choose this relay with lead or without lead (RoHs compliant)
1.5 For more extra request on this relay plz feel free to contact us.
2.Application:
The typical application of this 40A new energy relay is AC slow charging pile.However if you would to adopt it into new area, plz don't hesitate to communicate with us at any time.The technical support and before-sales service are free for you.